- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Bindeman, Ilya (1)
-
Cionoiu, Katharina (1)
-
Di Rocco, Tommaso (1)
-
Hertwig, Andreas (1)
-
McKeegan, Kevin D. (1)
-
Pack, Andreas (1)
-
Schmidt, Sebastian (1)
-
Schmitt, Axel Karl (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
A synthetic laser ruby crystal (HD-LR1) is introduced as a new matrix-matched reference material for secondary ionization mass spectrometry (SIMS) analysis of oxygen isotopes in corundum. Laser fluorination isotope ratio mass spectrometry (LF-IRMS) bulk analyses of multiple mg-sized fragments are homogenous, averaging δ18O = +18.40 ± 0.14‰ (95% confidence interval, n = 23) and Δ′17O = −0.368 ± 0.005‰ (as deviation from slope 0.528 for δ′17O vs. δ′18O at 95% conf., n = 11) relative to Vienna Standard Mean Ocean Water (V-SMOW). SIMS spot analyses show homogeneous O-isotopic values at the ng-scale independent of the location in the HD-LR1 single crystal and in four different crystallographic orientations. However, sample surface topography as an artefact of polishing corundum embedded in epoxy creates excess variability in δ18O within ∼100 μm from the edges of the grains. HD-LR1 is a chemical pure crystal with only Cr as a trace component detected at 276 μg g−1 by EPMA, whereas Be, often introduced in artificial gem enhancement, is <0.002 μg g−1 based on SIMS analyses. Therefore, HD-LR1 can also be used as a reference material for Cr, or as a blank for other trace element analyses of corundum by SIMS or LA-ICP-MS.more » « less
An official website of the United States government
